Mobile PC-Based PID Meter
A new monitoring kit for measuring total volatile organic compounds (TVOCs), along with indoor air quality parameters, the DirectSense TVOC comes with a 10.6 eV PID sensor for ppb range or ppm concentration range measurement of TVOCs. Relative humidity and temperature sensors are also included. Users can mix or match up to three electrochemical gas sensors from a choice of O3, NH3, NO2, NO, SO2, H2S, HCN, ethylene oxide, oxygen, chlorine, HCl, hydrogen, arsine, CO and more.
GrayWolf Sensing Solutions
Trumbull, Conn.
(203) 416-0005
www.WolfSense.com

AM Air Monitoring System
A versatile system for open path FTIR gas analysis in a variety of applications, the AM Air Monitoring System can detect, identify and measure a wide range of compounds simultaneously, within seconds of startup. Analysis is on site through a continuous sampling path of up to 1,000 meters. It is perfect for industrial stack and/or fence-line monitoring and analysis.
Midac Corp.
Costa Mesa, Calif.
(714) 546-4322
www.midac.com

Detect Low-Level Benzene Leaks
An economical monitoring system that detects concentrations of benzene in ppm, the Air Check EX Benzene Monitor - designed for use in Class I, Div. 1, Groups B, C and D hazardous areas - responds to low-level leaks and releases in less than 30 seconds, yet is unaffected by humidity and other environmental conditions. It is available with a measuring range of 0 to 300 ppm.
PureAire Monitoring Systems Inc.
Lake Zurich, Ill.
(847) 726-6000
www.PureAireMonitoring.com

Wall-Mounted Flue Gas Analyzer
The new Optimiser is a wall-mounted flue gas analyzer that monitors stack emissions for efficient combustion of either natural gas, coke, propane, butane, light oil, or heavy oil. It works by using two separate probes to measure the temperature and oxygen content. From these measurements, it calculates the CO2 content and the process efficiency.
CEA Instruments Inc.
Emerson, N.J.
(201) 967-5660
www.ceainstr.com

GC Columns for Higher Stability
Thermo has announced two new additions to its recently launched range of Trace GC columns and consumables to complement the company's GC and GC/MS instruments, the Trace TR-WaxMS and the Trace TR-1701 capillary columns. The new columns are characterized by a high temperature range and low bleed levels, leading to higher sensitivity, less need for instrument cleaning and longer column lifetimes.
Thermo Electron Corp.
Boston, Mass.
(800) 532-4752
/www.thermo.com/columns

Water-Based CPCs
The Model 3782 water-based condensation particle counter (CPC) is a lower-cost instrument that detects particles down to 10 nm, in concentrations less than 50,000 particles/cm3. The Model 3785 CPC is a general-purpose instrument that detects particles down to 5 nm. Model 3786 detects ultra-fine particles as small as 2.5 nm. Because they use water as the condensing fluid, the CPCs are especially useful for indoor air-quality, environmental monitoring, atmospheric and climate studies, and cleanroom monitoring.
TSI Inc.
Shoreview, Minn.
(800) 677-2708
www.particle.tsi.com